Yaskawa MP920 Motion Module User Manual

Page 359

Advertising
background image

8.1 Overview of Alarms

8-3

8

SVA-01A/02A and PO-01

Run Status (RUNSTS)
IW

00

Bit1: PRMERR

Motion setting parameter setting error

Bit2: FPRMERR

Motion fixed parameter setting error

Out of range parameter number (ERNO)
W

0F

Bit0: EOVER

Error counter over

Bit4: PGER

Cumulative number of rotations
received error

Alarms (ALARM)
IL

22

Bit1: OTF

Positive overtravel

Bit2: OTR

Negative overtravel

Bit3: SOTF

Positive software limit

Bit4: SOTR

Negative software limit

Bit5: SVOFF

Servo power OFF

Bit17: ABSOVER ABS encoder count exceeded

Bit18: PGLFLT Broken PG wire error

Motion program alarms

Alarm output status
specified from the Group
Definitions Window

Program alarms

2h: Zero

division

error

10h: Circumference specified alarm with
radius specified

11h: Interpolation feed speed exceeded

12h: No interpolation feed speed

20h:

REG

data

error

Axis alarms

80h: Logical axis use disabled

81h: POSMAX exceeded in infinite length

axis

designation

82h: Distance the axis moved exceeded

LONG_MAX

89h: Beyond the ACC/SCC/DCC setting
range

Displays the execute/error status of Motion
Modules: 7-segment LED indicator

Motion Module LED indicator

Advertising