Yaskawa MP920 Motion Module User Manual
Page 359

8.1 Overview of Alarms
8-3
8
SVA-01A/02A and PO-01
Run Status (RUNSTS)
IW
00
Bit1: PRMERR
Motion setting parameter setting error
Bit2: FPRMERR
Motion fixed parameter setting error
Out of range parameter number (ERNO)
W
0F
Bit0: EOVER
Error counter over
Bit4: PGER
Cumulative number of rotations
received error
Alarms (ALARM)
IL
22
Bit1: OTF
Positive overtravel
Bit2: OTR
Negative overtravel
Bit3: SOTF
Positive software limit
Bit4: SOTR
Negative software limit
Bit5: SVOFF
Servo power OFF
Bit17: ABSOVER ABS encoder count exceeded
Bit18: PGLFLT Broken PG wire error
Motion program alarms
Alarm output status
specified from the Group
Definitions Window
Program alarms
2h: Zero
division
error
10h: Circumference specified alarm with
radius specified
11h: Interpolation feed speed exceeded
12h: No interpolation feed speed
20h:
REG
data
error
Axis alarms
80h: Logical axis use disabled
81h: POSMAX exceeded in infinite length
axis
designation
82h: Distance the axis moved exceeded
LONG_MAX
89h: Beyond the ACC/SCC/DCC setting
range
Displays the execute/error status of Motion
Modules: 7-segment LED indicator
Motion Module LED indicator