Yaskawa MP920 Motion Module User Manual

Page 135

Advertising
background image

4.2 Parameter List by Module

4-15

4

35

Rapid Traverse
Speed
(RV)

OL††22

0 to 2

31

-1

(Default = 3000)

1 = 10

n

reference units/min (n = Number of

digits below decimal)
Pulse unit: 1 = 100 pulses/min
mm unit: 1 = 1 mm/min
deg unit: 1 = 1 deg/min
inch unit: 1 = 1 inch/min

1 = 10

n

reference units/min (n = Number of

digits below decimal)
Pulse unit: 1 = 100 pulses/min
mm unit: 1 = 1 mm/min
deg unit: 1 = 1 deg/min
inch unit: 1 = 1 inch/min

37

External Posi-
tioning Travel
Distance
(EXMDIST)

OL††24

-2

31

to 2

31

-1

(Default = 0)

1 = 1 reference unit

1 = 1 pulses for
pulse unit

39

Stopping
Distance
(STOPDIST)

OL††26

-2

31

to 2

31

-1

(Default = 0)

1 = 1 reference unit

Used for motion
control

41

Step Travel
Distance
(STEP)

OL††28

0 to 2

31

-1

(Default = 0)

1 = 1 reference unit

43

Zero Point
Return Final
Travel Distance
(ZRNDIST)

OL††2A

-2

31

to 2

31

-1

(Default = 0)

1 = 1 reference unit

45

Override
(OV)

OW††2C 0 to 32767

(Default = 10000)

1 = 0.01%
(10000 = 100.00%)

46

Position Control
Flags
(POSCTRL)
(Default = 0, all
bits OFF)

OW††2D Bit 0: MLK

Machine Lock Mode Setting
0: OFF
1: ON (Machine Lock Mode setting)

Bit 1: TPRSREQ

Request for Preset Num-
ber of POSMAX Turns

0: OFF, 1: ON

Bit 2: ABSLDREQ

ABS System Infinite
Length Position Control
Data
LOAD request

0: OFF, 1: ON

Bit 3: PUNITSEL

Position Monitor 2 (IL††84) Unit Selection
0: Reference unit
1: Pulse unit

Bits 4 to 11

Not used.

Bits 12 to 15: USR-
MONSEL

Servo Driver User Moni-
tor Information Selection

Setting range:
0 to 4
Refer to the rele-
vant servo driver
user’s manuals.

Table 4.3 Motion Setting Parameters (cont’d)

No.

Name

Register

Number

Setting Range/

Bit Name

Meaning

Remarks

SVA

-01A

SVA

-02

A

SVB

-01

PO-

01

Advertising