When motion commands are not used, When motion commands are used – Yaskawa MP920 Motion Module User Manual

Page 65

Advertising
background image

2.3 Position Control

2-39

2

When Motion Commands Are Not Used

When motion commands are not used, the Speed Reference Selection Flags are disabled,
and the speed-related parameters have the meanings shown in the following table.

When Motion Commands Are Used

When motion commands are used, the meanings of the speed-related parameters differ
according to the Speed Reference Selection (bit 13 of OW††01).

Parameter No.

Name

Description

Bit 3 of OW††01

Speed Reference Value
Selection

Invalid

OW††0A

Approach Speed Setting

Specified as a percentage (%) of the rated
speed.

OW††0B

Creep Speed Setting

Specified as a percentage (%) of the rated
speed.

OW††15

Speed Reference Setting

The rapid traverse speed is specified as a per-
centage (%) of the rated speed.

OL††22

Rapid Traverse Speed

Invalid

OW††2C

Override

Invalid

Bit 13 of

OW††01

Parameter

No.

Name

Description

0

OW††0A

Approach Speed Setting

Specified using the reference unit.

OW††0B

Creep Speed Setting

Specified using the reference unit.

OW††15

Speed Reference Setting

Invalid

OL††22

Rapid Traverse Speed

Specified using the reference unit.

OW††2C

Override

Valid

1

OW††0A

Approach Speed Setting

Specified as a percentage (%) of the
rated speed.

OW††0B

Creep Speed Setting

Specified as a percentage (%) of the
rated speed.

OW††15

Speed Reference Setting

The rapid traverse speed is specified
as a percentage (%) of the rated
speed.

OL††22

Rapid Traverse Speed

Invalid

OW††2C

Override

Valid

Advertising