2.3 Position Control

2-35

2

With the SVA-02A Module (2-axis Servo Module), there are position buffers for only 2 axes.

Using the Position Buffers

By first storing in the position buffers the position information for a machine whose operat-
ing pattern has been determined in advance, continuous positioning of up to 256 points is
enabled simply by refreshing the buffer pointer at the completion of a single-block opera-
tion.

Writing to Position Buffers

1. Set the Position Buffer Access Number (OL††38). Any number between 1 and 256

can be set.

2. Set the Position Buffer Write Data (OL††3A).

3. Set Position Buffer Write (OB††21E) in the Motion Command Control Flags to ON.

1
2
3

256

1
2
3

256

1
2
3

256

1
2
3

256

OW

01

RUN Command Settings

Position Reference Setting

Position Buffer Access Number

Position Buffer Write Data

Position Buffer Read Data

Motion Control Flags

OL

12

OW

21

OL

38

OL

3A

IL

28

CPU Module

SVA Module

Axis 1 position buffers

Axis 2

Axis 3

Axis 4

INFO

CPU Module

96

123456

OW

21

OL

38

OL

3A

1

2

3

256

1

2

3

256

1

2

3

256

1

2

3

256

96

123456

SVA Module

Axis 2

Axis 3

Axis 4

Axis 1 position buffers