Using the position buffers, Writing to position buffers – Yaskawa MP920 Motion Module User Manual
Page 61

2.3 Position Control
2-35
2
With the SVA-02A Module (2-axis Servo Module), there are position buffers for only 2 axes.
Using the Position Buffers
By first storing in the position buffers the position information for a machine whose operat-
ing pattern has been determined in advance, continuous positioning of up to 256 points is
enabled simply by refreshing the buffer pointer at the completion of a single-block opera-
tion.
Writing to Position Buffers
1. Set the Position Buffer Access Number (OL38). Any number between 1 and 256
can be set.
2. Set the Position Buffer Write Data (OL3A).
3. Set Position Buffer Write (OB21E) in the Motion Command Control Flags to ON.
1
2
3
256
1
2
3
256
1
2
3
256
1
2
3
256
OW
01
RUN Command Settings
Position Reference Setting
Position Buffer Access Number
Position Buffer Write Data
Position Buffer Read Data
Motion Control Flags
OL
12
OW
21
OL
38
OL
3A
IL
28
CPU Module
SVA Module
Axis 1 position buffers
Axis 2
Axis 3
Axis 4
INFO
CPU Module
96
123456
OW
21
OL
38
OL
3A
1
2
3
256
1
2
3
256
1
2
3
256
1
2
3
256
96
123456
SVA Module
Axis 2
Axis 3
Axis 4