Operations Subject to Password Protection

If you configure a password for a user account assigned to a security group to protect access to data, access to data
is password protected. The operations that are subject to password protection and the security group that the
password is valid for are as follows.

*1 External memory inserted into the MICRO/I (HG2G-5F, HG3G/4G, HG2F/3F/4F only)
*2 HG2G-5F, HG3G/4G only
*3 HG3F/4F only

Operations subject to password protection

Security group that the password is valid for

Administrator

Operator

Reader

Data editing

Opening projects

YES

NO

NO

Reusing screens

YES

NO

NO

Modifying data

Downloading project data

YES

NO

NO

Downloading PLC programs

*2

from external

memory

*1

to hosts

YES

NO

NO

Downloading data to external memory

*1

YES

NO

NO

Downloading data to external memory

*1

while the

MICRO/I is running

YES

YES

NO

Uploading project data

YES

NO

NO

Uploading PLC programs

*2

from hosts to external memory

*1

YES

NO

NO

Uploading external memory data

*1

YES

YES

YES

Deleting all data

YES

NO

NO

Deleting external memory data

*1

YES

NO

NO

Formatting external memory

*1

YES

NO

NO

Switching to the system menu

YES

NO

NO

Displaying Device Monitor

YES

YES

NO

Copying files from a USB flash drive to an SD memory card

*1

YES

YES

NO

Copying files from an SD memory card to a USB flash drive

*1

YES

YES

YES

Executing the USB Autorun function

*2

YES

NO

NO

Remotely monitoring the MICRO/I state from a web
browser terminal

*2

YES

YES

YES

Remotely operating the MICRO/I state from a web
browser terminal

*2

YES

YES

NO

Opening Device Monitor on a web browser terminal
and reading device values

*3

YES

YES

YES

Opening Device Monitor on a web browser terminal
and changing the values of internal devices

*3

YES

YES

NO

• For the HG2G-S/-5S/-5F and the HG3G/4G, you can set a dedicated password. In the Security dialog

box, on the Options tab, select the Use Password to open a Project check box, and then set the
password. The dedicated password is applicable to the following operations:
- Opening projects
- Reusing screens
- Opening projects after uploading project data
- Opening projects after uploading data on external memory

*1

• To password protect operations, the lowest level security group out of the security groups enabled with a

password must be assigned to a user account.
The security levels, from highest to lowest, are Administrator > Operator > Reader.
Example: To password protect the operation to display Device Monitor, assign the Operator security

group to a user account. If a user account assigned to the Operator security group does not
exist, the operation is not password protected.