Rec ipe func tion – IDEC High Performance Series User Manual

Page 933

Advertising
background image

WindO/I-NV2 User’s Manual

18-7

2 Recipe Function Configuration Procedure

18

R

ec

ipe

Func

tion

14

Enter the file name for the recipe file in File Name.
The file name that can be set depends on the O/I type.

15

Select the operation using the data for the recipe under Trigger Setting.
This option is set by block.

Read/Write
Save batch read device values to the memory card as a recipe file or write them to devices as recipe values.
This option can only be configured when Memory Card is selected under Access to.

Read-only
Save batch read device values to the memory card as a recipe file.
This option can only be configured when Memory Card is selected under Access to.

Write-only
Write recipe values to devices.

If you select Write-only, proceed to step

17

.

16

Specify the device that triggers batch reading device values and saving them to the memory card as a recipe file in
Read Trigger.
This option is set by block.

Click

to display the Device Address Settings dialog box.

For the device address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
This option can only be configured when Read/Write or Read-only is selected under Trigger Setting.
If you selected Read-only, proceed to step

18

.

17

Specify the device that triggers batch writing recipe values to devices in Write Trigger.
This option is set by block.

Click

to display the Device Address Settings dialog box.

For the device address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
This option can only be configured when Read/Write or Write-only is selected under Trigger Setting.

18

Click OK to close the Individual Settings dialog box.
You are returned to the Recipe Settings dialog box.

19

Repeat steps

3

through

18

to register data for the recipe to all the used channels.

20

Click OK.
The Recipe Settings dialog box closes.

For details on how to create and edit the data for recipes, refer to “4 Creating and Deleting Data for Recipes” on page
18-14.

HG2G-5F, HG3G/4G:

The default is “RCPn.CSV”. (n: 4 digit sequential number)
To change the file name, enter a new file name. The maximum number is 120 characters
(including the extension).
The file is overwritten when there is a recipe file with the same name on the memory
card.

HG2F/3F/4F:

The file name is “RCPn.CSV”. (n: 4 digit sequential number)
This cannot be changed.

Advertising