IDEC High Performance Series User Manual

Page 878

Advertising
background image

4 Using the Data

14-40

WindO/I-NV2 User’s Manual

10

Select the specification method for the amount of data to copy in Number of Data.

Value
Use a constant.
Specifies the amount to copy (1 to 64).

Device
Use a word device.
Specifies the source word device. You can only specify an internal device.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer

to Chapter 2 “5.1 Device Address Settings” on page 2-67.

11

Select the order to copy data in Stored Order of Data.

From Newest to Oldest
Of the data to copy, copies from the start point in order of the newest data first.

From Oldest to Newest
Of the data to copy, copies from the start point in order of the oldest data first.

12

Select the data to copy from the data in Target Data.
Select the Sampling Time check box to copy the sampling time data from the data.
Select the Value of Device check box to copy the value of device from the data. When not copying the value of
device, proceed to step

15

.

13

Select the specification method for the data number to copy the value in Data No..

Value
Use a constant.

Device
Use a word device.

14

Specify the data number of the data to start copying out of the data to copy with Start No..
If you select Value, specify the data number (1 to 128).

If you select Device, specify the source device. You can only specify an internal device. Click

to display the

Device Address Settings dialog box. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-67.
When the Sampling Time check box is selected, the data number is 1. This cannot be changed.

15

Specify the data number of the data to end copying out of the data to copy with End No..
If you select Value, specify the data number (1 to 128).

If you select Device, specify the source device. You can only specify an internal device. Click

to display the

Device Address Settings dialog box. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-67.

16

Select the condition to start copying in Trigger Condition.

Always
Copies each time the data is updated.

Device
Specifies the device that triggers the start of copying the data. Copies the data when the value of the specified device
changes from 0 to 1. Click

to display the Device Address Settings dialog box. For the device address

configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

17

Click OK to close the Individual Settings dialog box.
You are returned to the Data Log Settings dialog box.

The maximum amount of data that can be copied to the internal device is 64, regardless of data size.