Data t ransf er func tion – IDEC High Performance Series User Manual

Page 1221

Advertising
background image

WindO/I-NV2 User’s Manual

28-27

2 PLC Program Transfer Function

28

Data T

ransf
er Func

tion

11

Press COPY.
A process confirmation message is displayed.

12

Specify the MICRO/I communication port and PLC network number or station number, and then press YES.
The PLC program file download starts.
When the download finishes, the results are displayed.

13

Press Ack to close the results screen.
You are returned to the top page of system mode.

Main

Menu

---

File

Manager

---

DEL

RELOAD

ENT

COPY

DIRECTION

FILTER

ALL

FILTERS

DRIVE:
SD card

FORMAT

DRIVE:
PLC

FORMAT

HGDATA01

<DIR>

PLOGRAM01.zld

PLC.ZLD

YES

NO

Copy This File ?

PLOGRAM01.zld

Comm.I/F:

Network Number:

Communication port

Network number or
station number

0

0

0

SERIAL 1

When downloading a PLC program file to a PLC configured with a password, the PLC password screen is
displayed. Enter the password.