IDEC High Performance Series User Manual

Page 664

Advertising
background image

10 Calendar

10-152

WindO/I-NV2 User’s Manual

ON Time
Configures the time to write 1 to the report device according to the type of data.

OFF Time
Select this check box to configure the time to write 0 to the report device.
The time is configured according to the type of data.

Report Device
Specifies the bit device to write the value to at ON Time and OFF Time.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer

to Chapter 2 “5.1 Device Address Settings” on page 2-67.

• After 1 is written to the report time with ON Time, that value is retained.

• After a screen configured with the Calendar is displayed, if the time is in between ON Time and OFF

Time, 1 is written to the report device.

Value of device retained after ON Time elapses

1

0

09:00

09:30

10:00

10:30

11:00

Report device

M0 value

Time

ON Time

Turn on MICRO/I power
Open screen

1

0

09:00

09:30

10:00

10:30

11:00

Report device

M0 value

Time

ON Time

Writes 1 to noƟfy that ON Time has already elapsed

OFF Time

• The value of report device is retained even when the current time exceeds OFF Time.

• After a screen configured with the Calendar is displayed, if the time exceeds OFF Time, 0 is written to

the report device.

Value of device retained after OFF Time elapses

1

0

10:00

10:30

11:00

11:30

12:00

Report device

M0 value

Time

OFF Time

Turn on MICRO/I power
Open screen

Report device

M0 value

1

0

Time

10:00

10:30

11:00

11:30

12:00

OFF Time

Writes 0 to noƟfy that OFF Time has already elapsed

ON Time

Advertising
This manual is related to the following products: