Lamps – IDEC High Performance Series User Manual

Page 491

Advertising
background image

WindO/I-NV2 User’s Manual

9-11

1 Pilot Lamps

9

Lamps

Trigger Type: Selects the condition to display the Pilot Lamp from the following.

Always visible: The Pilot Lamp is always displayed.

While ON:

Displays the Pilot Lamp when the device value is 1.

While OFF:

Displays the Pilot Lamp when the device value is 0.

While satisfying the condition:

Displays the Pilot Lamp when the condition is satisfied.

Data Type:

Selects the type of data handled by the conditional expression for the visible condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.

Device:

Specifies the bit device or bit of the word device to serve as the visible condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.

Click

to display the Device Address Settings dialog box. For the device address configuration

procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Condition:

Specifies the conditional expression for the visible condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type
.

Click

to display the Trigger Condition Settings dialog box. For the conditional expression

configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.

Comment:

Used for entering a comment for the visible condition. The maximum number is 80 characters.

Always show

Pilot Lamp state

1

0

Hide

Show

Hide

Hide

Show

Show

Device value

Pilot Lamp state

1

0

Show

Show

Show

Hide

Hide

Hide

Device value

Pilot Lamp state

Pilot Lamp state

Hide

Hide

Hide

Show

Show

Show

Satisfied

Not satisfied

Condition