3 properties of pilot lamp dialog box, General tab, Properties of pilot lamp dialog box -3 – IDEC High Performance Series User Manual

Page 483: Lamps

Advertising
background image

WindO/I-NV2 User’s Manual

9-3

1 Pilot Lamps

9

Lamps

1.3 Properties of Pilot Lamp Dialog Box

This section describes items and buttons on the properties dialog box.

General Tab

Part Name
Enter a name for the part. The maximum number is 20 characters.

>>OFF Text, >>ON Text
Applies the text entered in the Part Name field to the Text field under the OFF or ON fields on the Registration
Text
tab. This is used as the Registration Text when the lamp is OFF or ON.

Action Mode
Select the action when the part is ON.

To specify the Registration Text to use when the button is ON, select the Set by State check box on the
Registration Text tab. If left unchecked, the same Registration Text assigned for the OFF state is
displayed for the ON state as well.

No Flash (only ON): Displays the drawing object for the ON state when the trigger condition is satisfied.

Flash (ON + Flash): When the condition is satisfied and the value of the trigger device is 1, the object flashes

(alternates between the drawing object for the ON and OFF states at fixed intervals). The
flashing interval can be set with the Flashing Cycle setting on the System tab of the Project
Settings
dialog box.

Flash Trigger Device: Specify the bit device to cause the lamp to flash.

The lamp flashes when the value of the device is 1. The action for No
Flash (only ON)
applies when the value is 0.

Click

to display the Device Address Settings dialog box. For the

device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-67.