2 types and trigger conditions of the script, Types of scripts, Trigger condition of the script – IDEC High Performance Series User Manual

Page 966: Types and trigger conditions of the script -2

Advertising
background image

1 About the Script Function

20-2

WindO/I-NV2 User’s Manual

1.2 Types and Trigger Conditions of the Script

Types of scripts

There are 3 types of scripts used.

Script Command
This is a script that executes in accordance with trigger conditions in the same way as other parts, such as switches or
lamps, for each screen.

• It is executed only in the screens where it is placed.
• Multiple scripts can be set for each screen.

For details, refer to Chapter 12 “5 Script Command” on page 12-32.

Global Script
This is a script that operates within the whole project. This script is executed at the end of MICRO/I scan process in
accordance with the trigger condition. The amount of Global Scripts which can be used in a project is as follows. For
details about setup, refer to “3 Global Script” on page 20-12.

Cyclic Script

*1

This is a script that can be repeated in fixed intervals independent of the scan process of the MICRO/I. Input delay
and output delay of the expansion module can be kept to a minimum by this script.
Only one cyclic script can be set to a project.
For details, refer to Chapter 29 “3 Cyclic Script” on page 29-9.

Trigger condition of the script

Trigger conditions that can be set for the script are as follows:

Rising-edge
Script is executed when trigger device changes from 0 to 1.

Falling-edge
Script is executed when trigger device changes from 1 to 0.

Satisfy the condition
Script is executed when the set condition is met.
This can only be set for the Script Command.

While satisfying the condition
Script is executed while the set condition is met.
This can only be set for the Script Command.

Fixed Period
Script is executed at set intervals.

Always ON
Script is executed on every scan of the MICRO/I.
This can only be set for the Global Script.

*1 HG2G-5F, HG3G/4G only

HG2G-S/-5S/-5F, HG3G/4G:

16 scripts

HG1F/2F/2S/3F/4F:

One script

Script

Trigger Condition

Rising-edge

Falling-edge

Satisfy the

condition

While

satisfying the

condition

Fixed Period

Always ON

Script Command

YES

YES

YES

YES

YES

NO

Global Script

YES

YES

NO

NO

YES

YES

Fixed interval script

NO

NO

NO

NO

YES

NO