Use r ac counts and the sec urit y function – IDEC High Performance Series User Manual

Page 1089

Advertising
background image

WindO/I-NV2 User’s Manual

23-39

3 Security Dialog Box

23

Use
r Ac
counts and the Sec

urit

y Function

Status of Password Entry
Select this check box to monitor the entry status of the password on the Password screen. These settings can only be
configured when the Use Security functions check box is selected on the General tab.

The following bits change to 1 depending on the password input status. These bits become 0 when the Password
screen opens or when a button other than ENT or CAN is pressed on the Password screen.

Require a password automatically
Select this check box to automatically display the Password screen when the user attempts to switch to a base screen
that cannot be accessed with the current user account by using a Goto Screen Button or Goto Screen Command
configured with Switch to Base Screen for the Action Mode in the Properties dialog box. These settings can only
be configured when the Use Security functions check box is selected on the General tab.

(Destination device):

Specifies a word device to write the password entry status.

Click

to display the Device Address Settings dialog box. For the device address

configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Bit position

Function

Parameters

0

This bit stores the information when the correct password was
entered on the Password screen and ENT was pressed.

0: Password being entered
1: Correct password entered

1

This bit stores the information when an incorrect password was
entered on the Password screen and ENT was pressed.

0: Password being entered
1: Incorrect password entered

2

This bit stores the information when CAN was pressed on the
Password screen.

0: Password being entered
1: Password entry canceled

3 to 7

Reserved

-

Advertising
This manual is related to the following products: