background image

4 Clear

24-26

WindO/I-NV2 User’s Manual

Deletes data from the MICRO/I or from an external memory inserted in the MICRO/I.

4.1 Clear Data from the MICRO/I

1

Change communication settings according to the connection method between the computer and the MICRO/I.

In the Communication Settings dialog box, select MICRO/I from Communicate with. To communicate with the

MICRO/I as an O/I Link Slave via an O/I Link Master, select O/I Link Slave. For details, refer to “1.3 Change

Communication Settings” on page 24-6.

2

Open project data.

3

On the Online tab, in the Touch Screen group, click Clear, then click the data to be deleted.

All
Deletes project data, Alarm Log data, Data Log data, and Operation Log data

*1

. It also clears the HG Keep Register

(LKR) and HG Keep Relay (LK)

*2

.

Alarm Log Data
Deletes the data collected by the Alarm Log function.

Data Log Data
Deletes the data collected by the Data Log function.

Operation Log Data

*1

Deletes the data collected by the Operation Log function.

HG Keep Register (LKR) and HG Keep Relay (LK)

*2

Clears the HG Keep Register (LKR) and HG Keep Relay (LK).

Stored Data in Memory Card

*3

After stopping operation, deletes data saved to the Memory Card Folder on an external memory.
Click this to display the Clear Data dialog box. For details, refer to “4.2 Deleting Data from an External Memory
Inserted in the MICRO/I” on page 24-28
.

• When Communicate with is set to MICRO/I and Port to USB or Serial, deletion of the data starts.
• When Communicate with is set to MICRO/I and Port is set to Ethernet, the Target IP Address dialog box is

displayed. Specify the IP address of the MICRO/I, and then click OK to start deletion of the data. For details, refer
to “To execute any function except project data download” on page 24-9.

• When Communicate with is set to O/I Link Slave, the Target Slave dialog box is displayed. Specify the slave

station of the MICRO/I to communicate with, and then click OK to start deletion of the data.
If Port is set to Ethernet, specify the IP address of the master to be used. If Port is Ethernet and the via Web
Server Unit
check box is selected, specify the port number of the Web Server Unit connected to the destination
MICRO/I. For details, refer to “To execute any function except project data download” on page 24-11.

*1 HG2G-5F, HG3G/4G only
*2 HG2G-S/-5S/-5F, HG3G/4G only
*3 HG2G-5F, HG3G/4G, HG2F/3F/4F only

4

Clear

HG3G

HG2G-5F

HG2G-5S

HG2G-S

HG4G HG1F HG2F HG2S HG3F HG4F

If security is enabled in the MICRO/I project, the Password Screen is displayed. Enter the password.
For details, refer to Chapter 23 “User Accounts and the Security Function” on page 23-1.