WindO/I-NV2 User’s Manual

17-7

3 Preventive Maintenance Settings Dialog Box

17

Pr

ev

entiv

e Mainte

nanc

e Function

Edit
Registers or changes the settings for the selected number.
Select a number and click this button to display the Individual Settings dialog box. The configured content for the
selected number is reflected in the Individual Settings dialog box. For details, refer to “3.2 Individual Settings
Dialog Box” on page 17-8
.

Remove
Deletes the settings for the selected number.
Select a number and click this button.

Up
Shifts the selected settings upward in the list.

Down
Shifts the selected settings downward in the list.

Level 1 to 3 Threshold:

Shows the time as a constant or a device that is the criterion for reporting at level 1
through level 3. For a constant, double clicking the cell displays the Individual Settings
dialog box. For details, refer to “3.2 Individual Settings Dialog Box” on page 17-8. For a
device, the Device Address Settings dialog box is displayed. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
This option is only displayed when Operation Time or Operation Time + Operation
Count
is selected in Display Options.

Level 1 to 3 Report Device: Shows the bit device or bit of the word device for reporting when the operation time

reaches or exceeds the level 1 through level 3 thresholds.
Double clicking the cell displays the Device Address Settings dialog box. For the
device address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings”
on page 2-67.
This option is only displayed when Operation Time or Operation Time + Operation
Count
is selected in Display Options.

Operation Count Device:

Shows the destination device for the counted operation count. You can only specify an
HG keep register (LKR).
Double clicking the cell displays the Device Address Settings dialog box. For the
device address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings”
on page 2-67.
This option is only displayed when Operation Count or Operation Time + Operation
Count
is selected in Display Options.

Data Type:

Shows the date type of the operation count device. Double clicking the cell displays the
Individual Settings dialog box. For details, refer to “3.2 Individual Settings Dialog Box”
on page 17-8.
This option is only displayed when Operation Count or Operation Time + Operation
Count
is selected in Display Options.

Level 1 to 3 Threshold:

Shows the count as a constant or a device that is the criterion for reporting at level 1
through level 3. For a constant, double clicking the cell displays the Individual Settings
dialog box. For details, refer to “3.2 Individual Settings Dialog Box” on page 17-8. For a
device, the Device Address Settings dialog box is displayed. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
This option is only displayed when Operation Count or Operation Time + Operation
Count
is selected in Display Options.

Level 1 to 3 Report Device: Shows the bit device or bit of the word device for reporting when the operation count

reaches or exceeds the level 1 through level 3 thresholds.
Double clicking the cell displays the Device Address Settings dialog box. For the
device address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings”
on page 2-67.
This option is only displayed when Operation Count or Operation Time + Operation
Count
is selected in Display Options.