IDEC High Performance Series User Manual

Page 146

Advertising
background image

5 User Communication

3-44

WindO/I-NV2 User’s Manual

Registering Constant (Character)

From the registered character data, character data according to the value of device is read and transmitted.
This can be configured only when TXD is selected in Command Type on the Command Settings dialog box, and
Registering Constant (Character) is selected under Type on the Data Settings dialog box.

Number of Registering Constants
Specify the number of data of the registered character data (1 to 100).

Registering Constants

Index
Specify the Index No. (0 to 65535) of the character data.

Data
Enter the character data (1 to 1500 bytes) to be registered. The size of a single-byte character is one byte and that of
a double-byte character is two bytes.
The character data of different size or the same data with a different number cannot be registered.

Set
Register the Index and Data settings to the list. When a number that is already registered is selected, it is
overwritten with the new setting.

Insert
Insert a character data setting to the selected number in the list.
Click this button to insert the Index and Data setting. The settings at the insertion point shift down 1 line. Settings
cannot be inserted when all numbers are already set.

Delete
Delete the selected settings from the list.

Index Device
Specify the source word device to serve as the Index No. You can only specify an internal device.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer to

Chapter 2 “5.1 Device Address Settings” on page 2-67.

No.:

Shows the ID No. (1 to 100) of the character data.

Index:

Shows the Index No. of the character data.

Data:

Shows the character data.

Advertising