IDEC High Performance Series User Manual

Page 918

Advertising
background image

3 Preventive Maintenance Settings Dialog Box

17-10

WindO/I-NV2 User’s Manual

Data Type
Select the data type for the operation count device as BIN16 (+) or BIN32 (+). For details, refer to Chapter 2 “1.2
Available Data” on page 2-2.

Report when Operation Count has reached or exceeded Threshold level
Select this check box to report when the counted operation count reaches or exceeds the threshold.

(Data Type)
Selects the type of data for the threshold.

Level 1
Configures the level 1 threshold and report device.

Level 2
Select this check box to configure the level 2 threshold and report device.

Level 3
Select this check box to configure the level 3 threshold and report device.

Value:

Uses a constant as the threshold.

Device:

Uses a device value as the threshold.

Threshold

Specifies the count as a constant or a device that is the criterion for reporting at level 1. For a
constant, the range that can be set varies based on the data type. For a device, click

to

display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Report Device:

Specifies the bit device or bit of the word device for reporting when the operation count reaches
or exceeds the level 1 threshold.

Click

to display the Device Address Settings dialog box. For the device address

configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Threshold

Specifies the count as a constant or a device that is the criterion for reporting at level 2. For a
constant, the range that can be set varies based on the data type. For a device, click

to

display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Report Device:

Specifies the bit device or bit of the word device for reporting when the operation count reaches
or exceeds the level 2 threshold.

Click

to display the Device Address Settings dialog box. For the device address

configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Threshold

Specifies the count as a constant or a device that is the criterion for reporting at level 3. For a
constant, the range that can be set varies based on the data type. For a device, click

to

display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Report Device:

Specifies the bit device or bit of the word device for reporting when the operation count reaches
or exceeds the level 3 threshold.

Click

to display the Device Address Settings dialog box. For the device address

configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Advertising
This manual is related to the following products: