7 Alarm List Display

10-106

WindO/I-NV2 User’s Manual

List Tab

The List tab is only displayed when New Message List is selected for Message Settings on the General tab.

Number of Blocks
Configures the devices that trigger messages to display and message switching as blocks (0 to 64).

Start Text ID
Specifies the Text Manager ID number (1 to 32000) of the message to display. The text ID numbers are sequentially
configured for all channels from the first block starting with the ID number configured here. Click

to display Text

Manager.

Device Setting Method
Selects the trigger device setting method.

(Block settings)
Registers and edits the messages to display for each block channel.

(Block settings)

1 block is composed of 16 channels. 1 device bit can be monitored for each channel. The maximum number
of device bits that can be monitored is 16 for each block.

Serial:

The trigger devices after the block number selected in the block settings are configured with
sequential addresses.

Random:

Configures trigger devices for each block number.

Block No.:

Shows the block numbers in the amount specified by Number of Blocks.
Double clicking the cell displays the Individual Settings dialog box. For details, refer to
“Individual Settings Dialog Box” on page 10-107.

Trigger Device:

Shows the word device to use as the condition to display messages.
Double clicking the cell displays the Device Address Settings dialog box. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
When Serial is selected for Device Setting Method, the trigger devices for block numbers after
the selected block number are automatically configured with the configured trigger device as the
starting address.

No. of Reg. Text: Shows the number of messages registered to the block.

Double clicking the cell displays the Individual Settings dialog box. For details, refer to
“Individual Settings Dialog Box” on page 10-107.

Edit:

Changes the block settings in list.
Select a block number in the list and click this button to display the Individual Settings dialog
box. For details, refer to “Individual Settings Dialog Box” on page 10-107.