IDEC High Performance Series User Manual

Page 1300

Advertising
background image

2 Internal MICRO/I Devices

32-8

WindO/I-NV2 User’s Manual

• LSD4 and 6 store the maximum value, and when the Base Screen is switched, they are reset.
• The values of LSD4 to 6 are included errors of +/- 10 msec.
• The values of LSD38 to 40 are included errors of +/- 10 msec.
• When registers LSD7, 8, 9, 10, 11 or 12 contain FFFF (H) and are incremented, the value becomes 0.
• When you reckon time by using LSD9, the time difference (in 10ms units) from the previous value can be

calculated.

• The range for the “Year” in LSD13 is 2000 to 2099, and reverts to 2000 after 2099.
• When “1” is written to LSD20, internal clock is updated by the contents of LSD21-26. After setting the

year, month, day, hour, minute, and second data in LSD21 to 26, writes a “1” to LSD20.

• The display format for LSD31 is set under “Screen No. Format” in Project Settings. (BCD, BIN)
• This data format for LSD32 is the same as “Screen No. Format” in Project Settings. (BCD, BIN)

If the screen number is not exist in the project, “No Screen Data” message will appear.
If 0xFFFF(Hex) is written to LSD32, MICRO/I will display System Menu Screen.
In case that the current screen is changed by System Area1 and LSD32 at the same instant, the screen
number of the System Area1 will be displayed.

• LSD42 stores Memory card error status. Error descriptions are as follows.

0: Normal
1: Card not inserted/Incompatible card
2: Format error
3: Access error/Insufficient memory in Memory card/Reading or writing failure.
4: Unsuccessful read of picture data

• For HG2G-5F, HG3G/4G, the data stored in LSD43 to 46 are stored in kilobytes. 1 K byte is 1024 bytes.

Values of less than 1 K byte are rounded up.

• By using the LSD50 value in the Message Switch Display you can display the message that corresponds

to the cursor in the Alarm List Display.

• Refer to Chapter 20 “1.4 Script Error” on page 20-4 for details regarding LSD52 and LSD53.
• LSD 55 is not supported by the HG2G-5F, HG3G/4G
• The following bit switched to ON while downloading to Memory card by WindO/I-NV2 or Downloader.

The bit switched to OFF after downloading.
Bit2: Recipe data
Bit4: Project data
Bit5: Picture data
Bit8: Sound data
Bit9: PLC Program

• LSM7 and LSD6, 102 to 107 are not available for Slave units when using O/I link communication.
• The maximum number of the Screen Captures stored in the Memory Card is set in LSD 65. The value in

LSD 65 can be anywhere from 1 to 999. (The default value is 99.)

• The error status for the multimedia function is stored in LSD 165. The error details are listed below.

0: Normal
1: Specified file does not exist
2: File format is incorrect
3: Specified parameter value is out of range