WindO/I-NV2 User’s Manual

10-47

3 Picture Display

10

Data Displa

ys

*1 HG2G-5F, HG3G/4G only

Value:

Switches the picture to display according to the value of the device.
Example: When Value is selected and the values of device D 0 are allocated to the following

pictures.

Switches the picture to display according to the value of the device.

Trigger Device:

Specifies the word device to use as the condition for switching pictures.

Click

to display the Device Address Settings dialog box. For the device

address configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-67
.
This option can only be configured when Bit or Value is selected.

0

1

2

Trigger device D 0 value

Picture

Pic2

Pic1

Pic0

Pic 1

Pic 0

Pic 2

0

Picture to display

Trigger device D 0

value

1

2

3

Display picture for 0

Action

Display picture for 1

Display picture for 2

No picture

If the value of device has

no picture associated

with it, display nothing.

When the size of pictures to switch differs and the Dynamic Size check box is cleared, all the pictures are
displayed with the same size as Pic0.

Fixed Period

*1

:

Switches the pictures to display at a regular interval in picture number order on the picture list.
Example: When Fixed Period is selected and the following pictures are allocated to the picture list.

Switches the pictures to display at a regular interval in picture number order on the
picture list.

Interval:

Specifies the interval to switch pictures as 1 to 3600 (100 ms units).
This option can only be configured when Fixed Period is selected.

Repeat:

Select this check box to repeat displaying pictures from the start of the picture
list when the picture at the end of the list is displayed.
This option can only be configured when Fixed Period is selected.

Picture

Picture list number

Pic2

Pic1

Pic0

Picture to display

Action

5 x 100 ms

Interval

Regular interval

5 x 100 ms

Regular interval

5 x 100 ms

Regular interval

Display picture

for bit 0

Display picture

for bit 1

Display picture

for bit 2

Pic 0

Pic 1

Pic 2

If the Repeat check box is cleared,

stop switching the picture list.

When Fixed Period is selected, the picture may not be displayed when the interval is shorter than the scan
time for the screen on the MICRO/I. The maximum value for the MICRO/I scan time can be checked by the
value of HG special register LSD 4. Refer to Chapter 32 “HG Special Registers (LSD)” on page 32-5.