background image

2 Character Input

10-34

WindO/I-NV2 User’s Manual

Visible Condition

*1

The Character Input is displayed while the condition is satisfied. The Character Input is hidden while the condition is
not satisfied.

*1 HG2G-5F, HG3G/4G only

While OFF:

Enables the Character Input when the value of device is 0.

While satisfying the condition:

Enables the Character Input when the condition is satisfied.

Data Type:

Selects the type of data handled by the conditional expression for the input condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.

Device:

Specifies the bit device or bit of the word device to serve as the input condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.

Click

to display the Device Address Settings dialog box. For the device address configuration

procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Condition:

Specifies the conditional expression for the input condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type
.

Click

to display the Trigger Condition Settings dialog box. For the conditional expression

configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.

Comment:

Used for entering a comment for the input condition. The maximum number is 80 characters.

1

0

Enabled

Enabled

Enabled

Disabled

Disabled

Disabled

Value of Device

Character Input

state

IDEC

IDEC

IDEC

IDEC

IDEC

IDEC

Disabled

Disabled

Disabled

Enabled

Enabled

Enabled

Satisfied

Not satisfied

Condition

Character Input

state

IDEC

IDEC

IDEC

IDEC

IDEC

IDEC

Example: When Trigger Type is While ON and Device is LM 0

While LM 0 is 0, the condition is not satisfied and the Character Input is hidden.
While LM 0 is 1, the condition is satisfied and the Character Input is displayed.

LM0:

MICRO/I

0

LM0: 1

Show

Condition

Satisfied

Condition

Not

satisfied

IDEC

Hide

• If the Character Input is hidden while entering a value, the input is canceled. If a popup screen

configured as the standard keypad or a keypad is displayed, these screens are closed.

• When multiple Character Inputs are arranged on the screen and the Focus is moved by ENT button

check box is selected, entry mode is canceled if the Character Input is hidden while entering a value.