Project set tings – IDEC High Performance Series User Manual

Page 217

Advertising
background image

WindO/I-NV2 User’s Manual

4-31

3 Project Settings Dialog Box

4

Project Set

tings

Storage Method of 32-bit Numerical Data

*1

Selects the handling method for device values when BIN32(+), BIN32(+/-), BCD8, or float32 is selected for
Data Type from the following.

Use Large Password Screen

*1

Select this check box to display the Password Screen at a large size.

*1 Advanced mode only

from Upper word:

Device values are read from and written to the upper order word.
Example: When Data Type for the Numerical Input is BIN32(+) and the numerical value

12345678 (hex) was entered and written to destination device LDR 100

from Lower word:

Device values are read from and written to the lower order word.
Example: When Data Type for the Numerical Input is BIN32(+) and the numerical value

12345678 (hex) was entered and written to destination device LDR 100

for FC3A/FC4A/FC5A:

The byte order varies based on device type.
This option can only be configured when the host I/F driver Manufacturer is IDEC and
Protocol is OpenNet,MicroSmart,SmartAXIS Pro/Lite(RS232C/485).

• Device types handled as from upper word

Data Register, Timer (Current), Counter (Current), Timer (Preset), Counter (Preset),
Special Data Register

• Device types handled as from lower word

Input (Word), Output (Word), Internal Relay (Word), Link Register, Special Internal Relay
(Word), Shift Register (Word)

Device

Stored value

LDR 100

1234 (hex)

Upper word

LDR 101

5678 (hex)

Lower word

Device

Stored value

LDR 100

5678 (hex)

Upper word

LDR 101

1234 (hex)

Lower word