Protecting the display of parts, Use r ac counts and the sec urit y function – IDEC High Performance Series User Manual

Page 1075

Advertising
background image

WindO/I-NV2 User’s Manual

23-25

2 Security Function Configuration Procedure

23

Use
r Ac
counts and the Sec

urit

y Function

Protecting the Display of Parts

Here you will configure the security group for a part to protect the display of that part.
This section describes an example where the display of the Line Chart is protected.

Configuration Procedure

1

Following the procedure in “Creating a User Account” on page 23-11, create the following user account.

2

Create a Line Chart and configure the display security group.
On the Home tab, in the Parts group, click Charts, and then click Line Chart.

3

Click a point on the edit screen where you wish to place the Line Chart.

4

Double-click the dropped Line Chart and the Properties dialog box is displayed.

Goto Screen Button

(Open password screen)

User2

No user

MICRO/I

MICRO/I

Line Chart

Can be displayed

Line Chart

Cannot

be displayed

To change the user account, a button or command is required to open the Password screen.

User Name

Security Group

GroupA

User2