WindO/I-NV2 User’s Manual

10-13

1 Numerical Input

10

Data Displa

ys

When Data Over
These options configure the operation of the part when the value entered with the keypad exceeds the allowable
range.
These options can only be configured when the Minimum or Maximum check boxes are selected under Range.

Example: If you attempt to enter “140”, which is higher than the maximum of “100”, or “-10”, which is lower than the

minimum of “0”, the value is not written and “?” is displayed. 1 is written to When Data Over report device
LM 0.

Report:

Select this check box to write 1 in the report device when the entered value or the value of the device
to display exceeds the allowable range.
Report Device: Specifies the report device.

Click

to display the Device Address Settings dialog box. For the device

address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on
page 2-67.

Operations

and

display

0

0

Entered data

80

80

80

?????

10

10

80

Written data

140

10

?????

10

80

10

-10

Data over notification: LM0

1

0

0

1

Range: Value

Minimum: 0

Maximum: 100

When Data Over

Report: On

Report device: LM0