1 Communicating with the MICRO/I

24-8

WindO/I-NV2 User’s Manual

Using the online function for Ethernet communication

Select Ethernet under Port on the Target IP Address dialog box.

To download project data

Click Download in the Download dialog box to display the Target IP Address dialog box.
Specify the Ethernet settings (IP address, subnet mask, and default gateway) for the MICRO/I.
Select the MICRO/I IP addresses and you can batch download project data to multiple MICRO/I.
It is also possible to change the Ethernet settings (IP address, subnet mask, and default gateway) for the MICRO/I to
which you are downloading after project data is downloaded.

Target List

Add
Adds a download destination for project data to the list. Click this button to open IP Address Manager. Using
IP Address Manager, specify the Ethernet settings for the MICRO/I to which you are downloading.

Delete
Deletes download destinations from the list.

Change Settings
Changes the Ethernet settings of the MICRO/I to which you are downloading after project data is downloaded.
Select a download destination from the list, and then click Change Settings to display IP Address Manager. Using
IP Address Manager, specify the Ethernet settings of the MICRO/I after downloading.

It is necessary to configure the MICRO/I according to the local network that is used.
On the Communication Interface tab in the Project Settings dialog box, specify the IP address, subnet
mask, and default gateway, and clear the Forbid Maintenance Communication check box. For details,
refer to Chapter 4 “3.2 Communication Interface Tab” on page 4-36.

The default network settings configured on the MICRO/I are as follows.

IP Address:

192.168.0.1

Subnet Mask:

255.255.255.0

Download to:

Shows the current IP address for the MICRO/I to download the project data to.

Set IP Address:

Shows the IP address for the MICRO/I after downloading the project data.

Set Subnet Mask:

Shows the subnet mask for the MICRO/I after downloading the project data.

Set Default Gateway:

Shows the default gateway for the MICRO/I after downloading the project data.

Port No.:

Shows the port number of the Web Server Unit connected to the MICRO/I to download the
project data to.
This can only be set when Ethernet is selected for Port and the via Web Server Unit
check box is selected on the Communication Settings dialog box.

Even if the Ethernet settings of the MICRO/I are changed by using the Target IP Address dialog box when
downloading a project, the Ethernet settings in the editing project data are not changed.