• Number of bytes and comparison data

When the converted data is 3034h, the data used for comparison with the BCC part of the receive data is as
follows.

• BCC data comparison

The comparison data is compared with the BCC part of the receive data.
In the following receive data, when the comparison data is the 1-byte 34h, there is a match since the BCC part data
is 34h.
When there is no match, the BCC Error (address+0, bit 0) of the Status Device changes to 1.

• When the calculation type is Modbus ASCII (LCR)

When the BCC calculation result is 4241h after Binary (HEX) to ASCII conversion the resulting two bytes of
data is used for comparison with the BCC part of the receive data.

• When the calculation type is Modbus RTU (CRC)

When the BCC calculation result is BA30h with no conversion the two bytes of data is used for comparison with
the BCC part of the receive data.

0

(30h)

4

(34h)

Comparison data

4

(34h)

Bytes: 1

Converted data

(Second byte) (First byte)

0

(30h)

4

(34h)

0

(30h)

4

(34h)

Comparison data

Bytes: 2

Converted data

(Second byte) (First byte)

1

(31h)

4

(34h)

5

(35h)

2

(32h)

STX

(02h)

3

(33h)

BCC

(34h)

CR

(0Dh)

Comparison data

Match

Receive data

BCC part

4

(34h)

B

(42h)

A

(41h)

B

(42h)

A

(41h)

Comparison data

4241h

Binary (HEX) to ASCII

Data

Bytes: 2

Converted data

(Second byte) (First byte)

BAh

30h

BAh

30h

BA30h

No conversion

Comparison data

Data

Bytes: 2

Converted data

(Second byte) (First byte)