Data displa ys – IDEC High Performance Series User Manual

Page 527

Advertising
background image

WindO/I-NV2 User’s Manual

10-15

1 Numerical Input

10

Data Displa

ys

Visible Condition

*1

The Numerical Input is displayed while the condition is satisfied. The Numerical Input is hidden while the condition is

not satisfied.

*1 HG2G-5F, HG3G/4G only

While OFF:

Enables the Numerical Input when the value of device is 0.

While satisfying the condition:

Enables the Numerical Input when the condition is satisfied.

Data Type:

Selects the type of data handled by the conditional expression for the input condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.

Device:

Specifies the bit device or bit of the word device to serve as the input condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.

Click

to display the Device Address Settings dialog box. For the device address configuration

procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Condition:

Specifies the conditional expression for the input condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type
.

Click

to display the Trigger Condition Settings dialog box. For the conditional expression

configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.

Comment:

Used for entering a comment for the input condition. The maximum number is 80 characters.

1

0

Enabled

Enabled

Enabled

Disabled

Disabled

Disabled

Value of Device

Numerical

Input state

123

123

123

123

123

123

Satisfied

Not satisfied

Disabled

Disabled

Disabled

Enabled

Enabled

Enabled

Numerical

Input state

Condition

123

123

123

123

123

123

Example: When Trigger Type is While ON and Device is LM 0

While LM 0 is 0, the condition is not satisfied and the Numerical Input is hidden.
While LM 0 is 1, the condition is satisfied and the Numerical Input is displayed.

LM0:

MICRO/I

0

LM0: 1

Show

Condition

Not

satisfied

Condition

Satisfied

123

Hide

• If the Numerical Input is hidden while entering a value, the input is canceled. If a popup screen

configured as the standard keypad or a keypad is displayed, these screens are closed.

• When multiple Numerical Inputs are arranged on the screen and the Focus is moved by ENT button

check box is selected, entry mode is canceled if the Numerical Input is hidden while entering a value.

Advertising