3 Data Log Settings Dialog Box

14-20

WindO/I-NV2 User’s Manual

Batch
Select this check box to batch output all the sampled data to the memory card.

All the data is saved on the memory card when the trigger devices changes from 0 to 1. If a file with the same name
already exists on the memory card, that file is overwritten. The maximum amount of output data is the amount
configured by the data storage area or 1024.

*1 Advanced mode only
*2 HG2G-5F, HG3G/4G only

MICRO/I

Data Log data (CSV)

Output to

memory card

Memory Card

Data Log data

Sampling

Time

Data001

Data002

Data003

01/01/2011

12:00:30

20

120

201

01/01/2011

12:01:30

21

121

204

01/01/2011

12:02:30

22

122

206

01/01/2011

12:03:30

23

123

206

01/01/2011

12:04:30

24

124

210

01/01/2011

12:05:30

25

125

210

01/01/2011

12:06:30

26

126

218

0

1

Trigger Device

Data to be output
(all)

Output stops if there is insufficient free space on the memory card. Memory card error information is stored
in HG special register LSD42.

Trigger Device:

Specifies the bit device that triggers batch output. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
Data is output to file when the trigger device changes from 0 to 1.

File Name:

Enter the file name for the output data or shows the file name.

HG2G-5F, HG3G/4G:

The default is “LOGOn.CSV”. (n: Data log channel number)
To change the file name, enter a new file name. The maximum
number is 120 characters (including the extension).

HG2F/3F/4F:

The file name is “LOGOn.CSV”. (n: Data log channel number)
This cannot be changed.

Specify File Name by Value of Device

*1*2

:

Select this check box to specify the name of the file for the output data with the value of the
device configured by (File Name Device).

(File Name Device):

Specifies the word device that is the source of the data to use as
the file name. The file name is set by reading the values
sequentially from the starting device specified with the file name
device and handling those values as character data up to the
character before NULL (00).
The maximum number of devices is 40 (80 single-byte characters).
You can only specify an internal device. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-67
.

Example: When the device specified by (File Name Device) is LDR100 and the text to set is

"IDEC":

The file name at this time becomes "IDEC.CSV".

LDR100
LDR101
LDR102

(File Name Device)

4844

(Hex)

4543

(Hex)

‘ I ’ ‘D’

‘E’ ‘C’

0000

(Hex)

(NULL)