IDEC High Performance Series User Manual

Page 1102

Advertising
background image

1 Communicating with the MICRO/I

24-10

WindO/I-NV2 User’s Manual

To download project data

Click Download in the Download dialog box to display the Target Slaves dialog box.
Specify the slave station number of the MICRO/I to which you are downloading. You can download project data to
multiple MICRO/Is.
Also, it is possible to change the slave station number the MICRO/I to which you are downloading after project data is
downloaded.

Target
Select slave stations (Slave 1 through Slave 15 of the download target).

Set Slave No.
The slave station number of the MICRO/I to which you are downloading is changed after project data is downloaded.
Specifies the new slave station number (1 to 15) applied to the MICRO/I after downloading a project data.

Master IP Address
Specifies the IP address of the O/I Link Master that is used to communicate between the O/I Link Slave and the
external device.

Click

to display IP Address Manager. Specify the IP address for the O/I Link Master with IP Address Manager.

This option can only be displayed when O/I Link Slave is selected for Communicate with and Ethernet is
selected for Port in the Communication Settings dialog box.

Port Number
Specify the port number (0 to 65535) of the Web Server Unit connected to the MICRO/I to download the project data
to.
This can only be set when O/I Link Slave is selected for Communicate with and Ethernet is selected for Port
and the via Web Server Unit check box is selected in the Communication Settings dialog box.

If the slave station number of the MICRO/I is duplicated after downloading, communication is not possible.

Even if the slave station number of the MICRO/I configured in the Target IP Address dialog box when
downloading a project is rewritten, project data remains unchanged during editing.