3-13

5 User Communication

3

Communic

ation

4

Set the time out (0 to 255) from when 1 frame of data has been received to when the next frame of data starts to be
received in Receiving Character Time Out (x100 msec).
A frame refers to a data string from the beginning to the end of a command. These setting items are used only with
receive command.

5

Click Edit.
The Command Settings dialog box is displayed.

6

Set Transmission (TXD) command.
Enter a comment for transmission command in Comment.
The maximum number is 40 characters.

7

Select TXD in Command Type.
Specify the transmitted data to the external device connected to the MICRO/I and the conditions for transmitting
data.

8

Specify the bit device or bit of the word device for reporting that data transmission was successfully completed in
Completed Device.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer to

Chapter 2 “5.1 Device Address Settings” on page 2-67.

9

Specify the destination word device for the transmitted data size and error information in Status Device.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer to

Chapter 2 “5.1 Device Address Settings” on page 2-67.

10

Set the wait time (0 to 255) from when the trigger condition is satisfied to when the data is transmitted in
Transmission Wait (x100 msec).

11

Select the condition to transmit data in Trigger Type under Trigger Condition from the following.

Rising-edge
Data is transmitted when the value of device changes from 0 to 1.
Specify the bit device or bit of the word device as the condition.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer to

Chapter 2 “5.1 Device Address Settings” on page 2-67.

Falling-edge
Data is transmitted when the value of device changes from 1 to 0.
Specify the bit device or bit of the word device as the condition.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer to

Chapter 2 “5.1 Device Address Settings” on page 2-67.