Data log function – IDEC High Performance Series User Manual

Page 877

Advertising
background image

WindO/I-NV2 User’s Manual

14-39

4 Using the Data

14

Data Log Function

4

Select Enable for Log function on the General tab and configure Data Size, Source, and Sampling Method.

5

Specify the number of devices to sample in Number of Data on the Data tab, and configure Display Type and
Data Type for each item of data in Settings.

6

Click the Options tab.

7

Select the Copy Data Log Data check box.

8

Specify the destination device for the copied data in Destination Device.
You can only specify an internal device.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer

to Chapter 2 “5.1 Device Address Settings” on page 2-67.

9

Select the data that is the start point for copying data in Starting Point.

Newest Data
Set the starting point to read as the newest data.

Oldest Data
Set the starting point to read as the oldest data.

Specify by Value of Device
Specifies which data from the oldest data to set as the starting point to read by value of device, and sets that data as
the starting point to read.
Specifies the source word device. You can only specify an internal device.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer

to Chapter 2 “5.1 Device Address Settings” on page 2-67.