Current fault has occurred has occurred pump fault, Current fault has occurred pump fault has occurred, Current fault – IDEC High Performance Series User Manual

Page 623: Current fault pump fault pump fault, Has occurred, Data displa ys

Advertising
background image

WindO/I-NV2 User’s Manual

10-111

7 Alarm List Display

10

Data Displa

ys

Line Spacing

*2

Selects the specification method for line spacing in the list and configures the line spacing.

*2 Advanced mode only

Set with Number of Lines:

Specifies the number of lines for the message to display for one alarm line.

Number of Lines:

Enter the number of lines (1 to 10). To completely display a message that
contains newlines, a number of lines that is equal to or greater than the number
of message lines is required.

When you enter a value in Number of Lines, Height (dots) is automatically calculated according
to the display area.
The relationship between the number of lines and the height (dots) is height (dots) = number of
lines x magnification H x 16.

Number of Lines Magnification H

Height

1

1

Ч

Ч 16 =

16 dots

Current fault

Current fault

has occurred
Pump fault

Pump fault

has occurred

2

1

Ч

Ч 16 =

Current fault
has occurred

Pump fault
has occurred

3

1

Ч

Ч 16 =

Current fault
has occurred

has occurred

Pump fault

3

2

Ч

Ч 16 =

Number of Lines Magnification H

Height

Number of Lines Magnification H

Height

32 dots

48 dots

Number of Lines Magnification H

Height

96 dots

When the message is 2 lines,

2nd line is not shown.

Since the alarm line spacing is adjusted with the number of lines for the message fixed, this option is
convenient to use when displaying multi-line messages.

Set with Dots: Specifies the line spacing for the message to display for one alarm line in dots.

Height (dots): Enter the height (8 to 160). To completely display a message, a height equal to or

greater than Magnification H x 16 dots x the number of message lines is required.

When Magnification H is 1
To display a one-line message, 1 x 16 = 16 dots, a height of 16 dots or higher is required.

To display a two-line message, 2 x 16 = 32 dots, a height of 32 dots or higher is required.

When Magnification H is 2
To display a one-line message, 1 x 32 = 32 dots, a height of 32 dots or higher is required.

To display a two-line message, 2 x 32 = 64 dots, a height of 64 dots or higher is required.

16 dots

Height

Current fault has occurred
Pump fault has occurred

Height

Height

16 dots

32 dots

Current fault

has occurred

has occurred

Pump fault

Current fault

Pump fault

When the message is 2 lines,

2nd line is not shown.

Height

32 dots

Current fault has occurred
Pump fault has occurred

Height

32 dots

Current fault

Current fault

Pump fault

Pump fault

Height

64 dots

has occurred

has occurred

When the message is 2 lines,

2nd line is not shown.

Advertising