Communic ation – IDEC High Performance Series User Manual

Page 157

Advertising
background image

WindO/I-NV2 User’s Manual

3-55

5 User Communication

3

Communic

ation

Example 3

When the trigger condition is satisfied, the received data is stored in devices in the following order.

Example 4

When the trigger condition is satisfied, the received data is stored in devices in the following order.

Example 5

When the trigger condition is satisfied, the received data is stored in devices in the following order.
Data from the beginning of the received data to Constant (Hexadecimal) data is stored in the device. Constant
(Hexadecimal)
data is not stored.

Item

Setting

Conversion Type

ASCII (HEX) to Binary

Device

LDR100

Use Reference Device

OFF

Number of bytes

2

Words

2

Variable

OFF

Item

Setting

Conversion Type

ASCII (DEC) to Binary

Device

LDR100

Use Reference Device

OFF

Number of bytes

2

Words

2

Variable

OFF

Item

Setting

Conversion Type

No Conversion

Device

LDR100

Use Reference Device

OFF

Storage Method of data

from Upper byte

Number of bytes

1

Words

3

Variable

ON

0012h

LDR100:

0034h

LDR101:

ASCII (HEX) to Binary

2

(32h)

Value of Device

1

(31h)

4

(34h)

3

(33h)

Received data

1

(31h)

2

(32h)

3

(33h)

4

(34h)

Order of reception

Words: 2

2 bytes

12

LDR100:

34

(DEC)
(DEC)

LDR101:

ASCII (DEC) to Binary

2

(32h)

Value of Device

1

(31h)

4

(34h)

3

(33h)

1

(31h)

2

(32h)

3

(33h)

4

(34h)

Order of reception

Words: 2

Received data

2 bytes

3100h

LDR100:

3300h

LDR101:

0000h

LDR102:

1

(31h)

Value of Device

The stored data is smaller than the
size specified for Words.

0 is stored.

NUL

(00h)

3

(33h)

NUL

(00h)

1

(31h)

3

(33h)

ETX

(03h)

Order of reception

Words: 3

Received data

Upper

Lower

from Upper byte

1 byte

Constant (HEX) data

Constant (Character) data
0 is stored.

Stored data

No

conversion

Insufficient by 1 word
0 is stored.

Advertising