WindO/I-NV2 User’s Manual

33-9

3 Settings

33

MICRO/

I Setup

Start Time (Start Time)
This item sets the amount of time (in minutes) until communication with the host device starts after MICRO/I power
ON. This can be used to synchronize boot times with the host machine. Press the “ENTER” button to apply the
entered value. Press the “CANCEL” button to cancel the entered value and display the currently set value.

Details (Details)
The following items can be set.

• Whether or not to have a sound made when a touch switch is pressed.
• Select the screen number to be displayed as a binary number or BCD (binary coded decimal).
• To set blink cycle.
• Display the error message in Japanese or English.

Select the item to change using the POSN UP (

) or POSN DOWN (

) buttons. The selected item is highlighted.

Each press of the [CHNG UP] or [CHNG DOWN] button changes the property of the selected item. Repeat this
procedure until the desired properties are displayed. Press the “ENTER” button to apply the entered value.

Default Screen No. (Default Screen No.)
This item sets the No. (as a decimal value) of the screen to display after power ON. Use the Keypad to enter the
value. Press the “ENTER” button to apply the entered value. Press the “CANCEL” button to cancel the entered value
and display the currently set value.

Password (Password)
Changes the password set for the user account.

For the HG2G-S/-5S/-5F and the HG3G/4G, press <- and -> to switch the user account.
Press the “Change Password” button to display the password input screen. Use the password input keys to enter a
password from 4 to 15 characters. Pressing the “ENTER (ENT)” button applies the entered password and closes the
password input screen. Pressing the “CLR” button clears the password input field.

The setting is not updated if you display another screen before applying the setting.

The setting is not updated if you display another screen before applying the setting.

• The setting is not updated if you display another screen before applying the setting.
• If the Default Screen No. is set to 0, MICRO/I will display the screen set in the host device instead of the

internal initial screen. For details, refer to Chapter 4 “System Area 1” on page 4-32.

HG2G-S/-5S/-5F, HG3G/4G: If security function is used, you will be able to change the password for the selected

user account (either as an administrator or other users registered in the security group)
from the touchscreen.

HG1F/2F/2S/3F/4F:

You can change the password if you are the "Administrator" in the security group.

• If you press “CAN” on the Password Screen, the setting is not updated and you return to the Password

Screen.

• Pressing the “ENTER (ENT)” button without entering a password disables the password function.

• When you do not assign a password to a project data, the Password is blank.
• If you forget your password, contact for sales representative.