WindO/I-NV2 User’s Manual

3-29

5 User Communication

3

Communic

ation

Not Clear Completed Device automatically
Select this check box when the value of the Completed Device is not set to 0 automatically after it changes to 1. This
can be configured when RXD is selected in Command Type.

Example: When Trigger Type in Trigger Condition is While ON, Device is LM100 and Completed Device is

LM101

When the Not Clear Completed Device automatically check box is not selected:
When data receiving is successfully completed, the value of the Completed Device LM101 changes to 1.
When the first data of the next frame is received, the value of the Completed Device LM101 changes to 0.

When the Not Clear Completed Device automatically check box is selected:
When data receiving is successfully completed, the value of the Completed Device LM101 is set to 1. Even
after the first data of the next frame is received, the value of the Completed Device LM101 does not
change to 0.

Value of Completed Device

LM101

Receive command

Value of LM100 when

Trigger Condition is

While ON

1

0

1

0

Receive data 1 frame

Receive data 1 frame

1

0

1

0

Receive data 1 frame

Receive data 1 frame

Value of Completed Device

LM101

Receive command

Value of LM100 when

Trigger Condition is

While ON