Pen (device) tab, Charts – IDEC High Performance Series User Manual

Page 703

Advertising
background image

WindO/I-NV2 User’s Manual

11-31

2 Line Chart

11

Charts

Pen (Device) Tab

The Pen (Device) tab is only displayed when Device Display is selected for Chart Type on the General tab.

Reference Device
Specifies the start address of the data to display on the chart.

Click

to display the Device Address Settings dialog box. For the device address configuration procedure, refer

to Chapter 2 “5.1 Device Address Settings” on page 2-67.
The data size for the devices is 16 bits.
Updating and erasing the display is controlled by the lower 2 bits of the start address value (control status).

The number of device values to display is specified by the value of start address + 1.
The device values from start address + 2 are displayed on the chart.
Example: If Reference Device is set to D 100, continuous devices are used starting from D 100. The used devices

are as follows.

Bit 15

Bit 0

Bit 2

0 : Do not update

1 : Update

0 : Do not erase

1 : Erase

Reserved

D 100
D 101
D 102
D 103
D 104

Control status (display operaƟon)

Number of data to display values on chart

Data to display values on chart

(Start address)

+1

+2

+3

+4

D 106 value

D 105 value

D 104 value

D 103 value

D 102 value

D 101 value

D 100 value

10

50

20

60

10

1

5

D102

D103

Device values

Displayed chart

D104

D105

D106

0

20

40

60

80

100

-20

120