3 Project Settings Dialog Box

4

Project Set

tings

When SERIAL 2 is selected under Interface Configuration

When USB is selected under Interface Configuration

*1 HG1F/2F/2S/3F/4F only
*2 HG2G-S, HG1F/2F/2S/3F/4F only

Serial Interface: Selects the standard for the serial interface to use from the following.

RS232C, RS422/485 2-wire, RS422/485 4-wire
RS422/485 4-wire
can only be configured when User Communication 1, User
Communication 2
, User Communication 3, or Sub Host Communication is selected for
Protocol.

Protocol:

Selects the protocol used by Serial Interface 2 from the following.
N/A, Printer

*1

, User Communication 1

*2

, User Communication 2

*2

, User

Communication 3

*2

, Sub Host Communication

This communication interface is not used when N/A is selected.

Baud Rate:

Selects the communication speed with the host from the following.
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

Selects the data length as 7 or 8.

Stop Bits:

Selects the stop bits as 1 or 2.

Parity:

Selects the parity from the following.
None, Odd, Even

HG3G

HG2G-5F

HG2G-5S

HG2G-S

HG4G HG1F HG2F HG2S HG3F HG4F

When the Enable Pass-Through check box is selected on the Host I/F Driver tab, only the Maintenance
Communication function can be used with Serial Interface 2.

The HG1F cannot simultaneously use Serial Interface 2 and the O/I Link Interface. Configure the interface
to use under Interface Configuration.

Protocol:

Selects the protocol used by the USB Interface as N/A or Printer.
This communication interface is not used when N/A is selected.

HG3G

HG2G-5F

HG2G-5S

HG2G-S

HG4G HG1F HG2F HG2S HG3F HG4F

The HG2G-5S USB interface is for Maintenance Communication only.