2 Editing and Management of the Script

20-6

WindO/I-NV2 User’s Manual

4

Enter Script Name.
Maximum number for the script name is 40 characters.

5

Select Data Type.

6

Code a program in Script.

7

When the script is finished, click OK.
The created script is shown in Script List.

8

Click Close.
A save confirmation message is displayed.

9

Click OK.
The scripts are saved in the project data and Script Manager closes.
If you click Cancel, Script Manager closes without saving the scripts.

Be sure to match the Data Type of the script with the types of data being used within the script.
For example, if the script contains numbers with decimals, the Data Type of the script would be float32. If
the script contains only whole numbers between 0 and 65,535, the Data Type of the script would be
BIN16[+].

To create a script using the samples provided by WindO/I-NV2, under Function List, select Category and
Function, and then click Insert Format. The sample shown in Format is inserted at the cursor position in
Script.

When you are in the following dialog boxes, clicking

will open the Script Manager. When you close the

Script Manager, you will be taken back to the original dialog box.

• Global Script General tab
• Script Command properties General tab
• Multi-function script properties for Multi-Buttons and Multi-Commands
• Project Settings Expansion Module tab