1 Numerical Input

10-4

WindO/I-NV2 User’s Manual

Keypad
Configures the keypad for entering values in the Numerical Input.

Display Type
Selects the display type for the value as Decimal or Hexadecimal.

Data Format

*2 Advanced mode only
*3 HG1F/2F/2S/3F/4F only

Use as Display for Keypad

*2*3

: Select this check box to only use the Numerical Input as a part to display the value

entered with the keypad.

Type:

According to the location where the keypad is configured, selects the type from the following.
Standard:

Uses the standard keypad. The standard keypad is the keypad configured as the
popup screen for the standard keypad (screen number 3000 to 3015).
This is the keypad for the type configured by Display Type.

Popup:

Uses a keypad configured as a popup screen.

Current Screen:

Uses the keypad configured on the same screen as the Numerical Input.

Screen No.:

Specifies the screen number of the popup screen configured as the keypad (1 to 3015).
This option can only be configured if Popup is selected for Type.

Adjust location automatically:

Select this check box to display the popup screen configured as the keypad in a
location where it will not overlap the Numerical Input.
This option can only be configured if Standard or Popup is selected for Type.

Coordinates X, Y:

Specifies the display location of the popup screen configured as the keypad.
With the upper-left corner of the screen as the origin, the X and Y coordinates are
the upper-left corner of the popup screen.
This option can only be configured when Popup is selected for Type and the
Adjust location automatically check box is cleared.

HG2G-S/-5S/-5F, HG3G/4G, HG1F: Specify the coordinates in 1 dot units.

X: 0 to (base screen horizontal size - 1)
Y: 0 to (base screen vertical size - 1)

HG2F/2S/3F/4F:

Specify the coordinates in 20 dot units.
X: 0 to (base screen horizontal size - 20)
Y: 0 to (base screen vertical size - 20)

Data Type:

Selects the type of data for the value.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.

Digits:

Specifies the digits to display. The range of digits that can be set varies based on the
display type and data type. The digits that can be set are as follows.

Display Type

Data Type

Digits

Decimal display

BIN16 (+), BIN16 (+/-)

1 to 5

BIN32 (+), BIN32 (+/-)

1 to 10

BCD4

1 to 4

BCD8

1 to 8

float32

1 to 10

Hexadecimal
display

BIN16 (+)

1 to 4

BIN32 (+)

1 to 8