IDEC High Performance Series User Manual

Page 136

Advertising
background image

5 User Communication

3-34

WindO/I-NV2 User’s Manual

When RXD is selected as Command Type:

Fixed Period:

Data is transmitted at a fixed time interval.

Data Type:

Select the data type handled by the conditional expression.
Can only be set if Satisfy the condition is selected as Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.

Device:

Specifies the bit device or bit of the word device to serve as condition. You can only specify the internal

device.
Can only be set if Rising-edge or Falling-edge is selected as Trigger Type.
Click

to display the Device Address Settings dialog box. For the device address configuration

procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Condition:

Sets the condition formula.
Can only be set if Satisfy the condition is selected as Trigger Type.
Click

to display the Trigger Condition Settings dialog box. For the conditional expressions

configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.

Period (sec): Specify the period for command execution from 1 to 3600 (seconds).

This is enabled only when Fixed Period is selected in Trigger Type.

Trigger Type: Selects the condition to be ready to receive data from the following.

Always Enabled: The MICRO/I is always ready to receive data.

While ON:

Ready to receive data when the value of device is 1.

While OFF:

Ready to receive data when the value of device is 0.

While satisfying the condition:

Ready to receive data while the condition is satisfied.

Data Type:

Select the data type handled by the conditional expression.
Can only be set if While satisfying the condition is selected as Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.

Device:

Specifies the bit device or bit of the word device to serve as condition. You can only specify the internal

device.
Can only be set if While ON or While OFF is selected as Trigger Type.
Click

to display the Device Address Settings dialog box. For the device address configuration

procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.

Condition:

Sets the condition formula.
Can only be set if While satisfying the condition is selected as Trigger Type.
Click

to display the Trigger Condition Settings dialog box. For the conditional expressions

configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.

Fixed time interval

Fixed time interval

Fixed time interval

Action

Execution

Execution

Execution

Action

Always Enabled

Value of Device

1

0

Enabled

Enabled

Enabled

Action

1

0

Enabled

Enabled

Enabled

Value of Device

Action

Enabled

Enabled

Enabled

Condition

Satisfied

Not satisfied

Action

Advertising