I/o signals, Output phase form – Yaskawa Sigma II Series Servo System User Manual

Page 109

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5 - 23

I/O Signals

I/O signals are described below.

Divided encoder signals are output.
Always connect these signal terminals when a position loop is formed in the host
controller for position control.
Set a dividing ratio at the following parameter.

The dividing ratio setting is not related to the gear ratio setting (Pn202 and 203) for
the servo amplifier electronic gear function during position control.

Output Phase Form

Output PAO CN1-33

Encoder Output Phase A

Speed/Torque Control,

Position Control

Output /PAO CN1-34

Encoder Output Phase /A

Speed/Torque Control,

Position Control

Output PBO CN1-35

Encoder Output Phase B

Speed/Torque Control,

Position Control

Output /PBO CN1-36

Encoder Output Phase /B

Speed/Torque Control,

Position Control

Output PCO CN1-19

Encoder Output Phase C

Speed/Torque Control,

Position Control

Output /PCO CN1-20

Encoder Output Phase /C

Speed/Torque Control,

Position Control

PG Dividing Ratio

Pn201

Forward

rotation

Reverse

rotation

Phase A

Phase C

t

t

Phase A

Phase B

Phase B

Phase C

90°

90°

Advertising