The following examples show how to select the pull-up resistor R1 so the input
current (I) falls between 7 and 15mA.

Open-collector Output, Example 2: Using a servo amplifier with an internal 12V
power supply

This circuit uses the 12V power supply built into the servo amplifier. The input
is not isolated in this case.

Sequence Input Circuit Interface

The sequence input circuit interface connects through a relay or open-collector

transistor circuit. Select a low-current relay, otherwise a faulty contact will result.

Output Circuit Interfaces

Any of the following three types of servo amplifier output circuits can be used.

Connect an input circuit at the host controller following one of these types.

Connecting to a Line-driver Output Circuit

Encoder serial data converted to two-phase (A and B phase) pulse output signals
(PAO, /PAO, PBO, /PBO), origin pulse signals (PCO, /PCO) and S phase

rotation signals (PCO, /PCO) are output via line-driver output circuits that

normally comprise the position control system at the host controller. Connect
the line-driver output circuit through a line receiver circuit at the host controller.

Application Examples

R1 = 2.2k

Ω with

V

CC

= 24V ±5%

R1 = 1k

Ω with

V

CC

= 12V ±5%

R1 = 180

Ω with

V

CC

= 5V ±5%

PL1, PL2, PL3 terminals

V

1.5V maximum

when ON

About

9mA

Servo amplifier end

Host

controller end

1.0kΩ

150Ω

/S-ON, etc.

Servo amplifier

Servo amplifier

/S-ON, etc.

24V

DC

50mA minimum

24V

DC

50mA minimum

24V

IN

24V

IN

3.3kΩ

3.3kΩ