Yaskawa Sigma II Series Servo System User Manual

Page 200

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-114

*1

This is the net value at the rated load. When actually selecting fuses, determine the capacity using the pre-
scribed derating.

*2

Operating characteristics (at 25°C): 2 seconds or more for 200%, 0.01 second or more for 700%

Notes: 1. A fast-operating fuse cannot be used because the servo amplifier power supply is a capacitor

input type. A fast-operating fuse may blow when the power is turned ON.

2. SGDH servo amplifiers do not have built-in ground protection circuits. To configure a safer

system, install a ground fault interrupter with or without a circuit breaker for protection against
overload and short circuit conditions.

Main Circuit

Power

Supply

Servo Amplifier

Model

Applicable Motor

Power Capacity per

Servo Amplifier

(kVA)

*1

Current Capacity per

MCCB or Fuse

(A

rms

)

*1, *2

Capacity

(kW)

SGDH-

Three-phase,

400V

0.45

05DE

SGMGH-05D

1.1

1.0

10DE

SGMGH-09D

2.3

3.4

SGMSH-10D
SGMUH-10D

1.5

15DE

SGMGH-13D

3.2

4.6

SGMSH-15D
SGMUH-15D

2.0

20DE

SGMGH-09D

4.9

7.1

SGMSH-10D

3.0

30DE

SGMGH-30D

6.7

9.7

SGMSH-30D
SGMUH-30D

5.0

50DE

SGMGH-44D A

10.3

14.9

SGMSH-40D A
SGMSH-50D A
SGMUH-40D A

6.0

60DE

SGMUH-55D A

12.4

17.8

7.5

75DE

SGMGH-75D A

15.4

22.3

11.0

1ADE

SGMGH-1AD A

22.6

32.7

15.0

1EDE

SGMGH-1ED A

30.9

44.6

22.0

2BDE

SGMBH-2BD A

36.7

100

30.0

3ZDE

SGMBH-3ZD A

50.1

150

37.0

3GDE

SGMBH-3GD A

61.8

150

45.0

4EDE

SGMBH-4ED A

75.2

225

55.0

5EDE

SGMBH-5ED A

91.9

225