3 minimum parameters and input signals, 1 parameters, 2 input signals – Yaskawa Sigma II Series Servo System User Manual

Page 85: 3 minimum parameters and input signals - 13, 1 parameters - 13 4.3.2 input signals - 13, 3 minimum parameters and input signals -13, Parameters -13, Input signals -13

Advertising
background image

Sigma II User’s Manual

Chapter 4: Trial Operation

4 - 13

4.3 Minimum Parameters and Input Signals

This section of this manual describes the minimum parameters and input signals required
for trial operation.

4.3.1

Parameters

See 7.1.6 Operation in Parameter Setting Mode for more details on setting

parameters.
Turn OFF power once after changing any parameter except Pn300. The change will
not be valid until power is restored.

Basic Parameters

Speed Control

Position Control

Changing Servomotor Rotation Direction

The wiring may be incorrect if the specified direction differs from the actual
direction of rotation. Recheck the wiring and correct if necessary. Use the following
parameter to reverse the direction of rotation.

4.3.2

Input Signals

Input signal selection settings through parameters can be used to eliminate the need
for external short circuits.

Pn000.1

Function Selection Basic Switches: Control Mode Selection

See 5.3.5

Pn300

Speed Reference

See 5.2.1

Pn201

Using the Encoder Signal Output

See 5.2.3

Pn200.0

Position Reference

See 5.2.2

Pn202

Using the Electronic Gear Function (Numerator)

See 5.2.5

Pn203

Using the Electronic Gear Function (Denominator)

See 5.2.5

Pn000.0

Switching Servomotor Rotation Direction

See 5.1.1

Signal Name

Pin

Number

Description

/S-ON

Servo ON

CN1-40

See 5.5.2 for more details on turning ON and OFF the servomotor.

Advertising