7 db unit, 7 db unit - 128, Db unit -128 – Yaskawa Sigma II Series Servo System User Manual

Page 214: Specifications

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-128

5.8.7

DB Unit

Large capacity amplifiers (22-55kW) do not have internal DB resistors. An external
DB unit is needed if dynamic braking function is required for the application.

Externally attach a DB unit to the amplifier.
This DB unit is used for dissipating motor EMF energy.
The DB unit does not need to be installed if the dynamic brake function is not
required.

Specifications

Use one of the following DB units according to the Amplifier model.

SDGH-

2BDE

3ZDE

3GDE

4EDE

5EDE

Regenerative DB Unit JUSP-

DB03

DB04

DB05

DB06

DB contactor and surge
absorbtion unit

Built into Amplifier

Built into DB unit

Resistance

0.8

Ω

Resistance Capacity

180W

300W

Allowable Load Moment of
Inertia

5 times the load moment of inertia at motor shaft.

Allowable Duty

Less than 1 time/H at maximum speed DB operation.

Advertising