Reference Pulse/Feedback Pulse Counter Monitor Display

The monitor display of reference pulse counter and feedback pulse counter is
expressed in 32-bit hexadecimal.

The display procedure is as follows:

Using the Hand-held Digital Operator

1.

Press the DSPL/SET key to select the monitor mode.

2.

Press the Up Arrow or Down Arrow key to select “Un00C” or “Un00D”.

3.

Press the DATA/ENTER key to display the data for the monitor number
selected in the above step.

4.

Press the Up Arrow or Down Arrow key to alternately display the

leftmost and the rightmost 16-bit data.

5.

Press both the Up Arrow AND Down Arrow keys simultaneously to clear
the 32-bit counter data.

6.

Press the DATA/ENTER key once more to return to the monitor number

display.

Using the Built-in Panel Operator

1.

Press the MODE/SET key to select the monitor mode.

2.

Press the Up Arrow AND Down Arrow keys to select “Un00C” or
“Un00D”.

3.

Press the DATA/SHIFT key for a minimum of one second to display the data for
the monitor number selected in the above step.

4.

Press the Up Arrow or Down Arrow key to alternately display the

leftmost 16-bit data and rightmost 16-bit data.

Leftmost 16-bit Data

Rightmost 16-bit Data