A.F1

A.F1: Power Line Open Phase

Display and Outputs

Note:

OFF:

Output transistor is OFF (alarm state).

ON:

Output transistor is ON.

Status and Remedy for Alarm

Note:

A and B tend to occur in a servo amplifier with a capacity of 500W or
higher.

Alarm Outputs

Alarm Code Output

ALM Output

ALO1

ALO2

ALO3

OFF

ON

OFF

OFF

Cause of the Problem

Solution

A

One phase (L1, L2, or L3) of the

main circuit power supply is dis-

connected.

• Check power supply.

• Check wiring of the main circuit

power supply.

• Check MCCB, noise filter, mag-

netic contactor.

B

There is one phase where the line

voltage is low.

Check power supply.

C

Servo amplifier defective.

Replace servo amplifier.

When the main circuit’s
power supply is turned ON.

When the control power

is turned ON.

C

A, B