Parameters

The specifications shown in shaded column are the modified items.

Cat.

Paramete

r No.

Name

Unit

Lower Limit

Upper

Limit

Factory

Setting

Remarks

Fu

nction

Se

le

ct

io

n

Parameters

Pn004

Function Selection

Application
Switches 4

*1

0000H

1110H

0000H

The

settings on

2nd and

3rd digits

are added.

Pn080

Function Selection

Basic Switches

(Only for linear
motors)

*1

0000H

1011H

0000H

The setting

on 3rd digit

is added.

Gain

Re

lated

P

a

ra

me

te

rs

Pn103

Moment of Inertia

Ratio

%

0

20000

0

Upper limit

is modified.

Pn10B

Gain-related

Application
Switches

*1

0000H

2314H

0000H

The setting

on 2nd digit

is added.

Pn110

Online Autotuning

Switches

0010H

3212H

0000H

Modificatio

n only for

large-

capacity

Servo
Amplifiers

*

2

Pn124

Automatic Gain

Switching Timer

ms

1

10000

100

Newly

added

Pn125

Automatic Gain

Switching Width

Reference

Unit

1

250

7

Newly

added

Advertising