Sigma II User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9 - 2

9.1 Servodrive Inspection and Maintenance

This section describes the basic inspections and maintenance of servomotors and servo
amplifiers and the procedures for replacing the battery for absolute encoders.

9.1.1

Servomotor Inspection

For inspection and maintenance of servomotors, follow the simple, daily inspection
procedures in the following table.
The AC servomotors are brushless. Simple, daily inspection is sufficient under most
conditions. The inspection and maintenance frequencies in the table are only

guidelines. Increase or decrease the frequency to suit the operating conditions and
environment.

Servomotor Inspection

*1

Measure across the servomotor FG and the U-phase, V-phase, or W-phase power line

During inspection and maintenance, do not disassemble the servomotor.

If disassembly of the servomotor is required, contact Yaskawa.

Action or

Problem

Frequency

Procedure

Comments

Vibration and

Noise

Daily

Touch and listen.

Levels higher than normal?

Exterior Dirt

According to degree

of contamination

Clean with cloth or com-

pressed air.

Insulation

Resistance

Measurement

At least every year

Disconnect servo amplifier

and test insulation resis-

tance at 500V. Must
exceed 10M

Ω.

*1

Contact Yaskawa if the insu-

lation resistance is below

10M

Ω.

Oil Seal

Replacement

At least every 5000

hours

Remove servomotor from

machine and replace oil

seal.

Applies only to motors with

oil seals.

Servomotor

Overhaul

At least every 20000

hours or 5 years

Contact Yaskawa.

The user should not disas-

semble and clean the servo-

motor.

IMPORTANT