Sigma II User’s Manual

Chapter 8: Ratings and Characteristics

8 - 42

Servo Amplifier Ratings and Specifications Table 2 (continued)

*1

The DC reactor connection terminals for power supplies designed to minimize the effects of

harmonics are not included in servo amplifiers with capacitites of 6kW or more.

Servo Amplifier Model

SGDH-

50

60

75

1A

1E

I/O Sig

nals

Po

si

tio

n

Output

Form

A-, B-, C-phase line driver

S-phase line driver (only with an absolute encoder)

Frequency Dividing Ratio

Any

Sequence Input

Signal allocation can be modified

Servo ON, P control (or Control Mode switching, forward/reverse motor rotation by

internal speed setting, zero clamping, reference pulse prohibited), forward run

prohibited (P-OT), reverse run prohibited (N-OT), alarm reset, forward current limit,

and reverse current limit (or internal speed selection)

Seq

uenc

Output

Fixed Output

Servo alarm, 3-bit alarm codes

Signal allocation can be modified

Positioning completed (speed coincidence), during servomotor rotation, servo ready,

during current limiting, during speed limiting, brake released, warning, selecting three

of the NEAR signals.

Inte

rnal

Func

tion

s

Dynamic Brake

Operated at main power OFF, servo alarm, servo OFF, or overtravel.

Regeneration

Built-in

External regenerative resistor.

Overtravel Stop

Dynamic brake stop at P-OT or N-OT, deceleration to a stop, or free run to a stop.

Electronic Gear

0.01

≤ A/B ≤ 100

Protection

Overcurrent, overvoltage, low voltage, overload, regeneration error, main circuit volt-

age error, heat sink overheated, no power supply, overflow, overspeed, encoder error,

overrun, CPU error, parameter error, etc.

LED Display

Charge, Power, five 7-segment LEDs (built-in digital operator functions)

CN5 Analog Monitoring

Analog monitor connector built in for monitoring speed, torque and other reference

signals.

Speed: 1V/1000rpm

Torque: 1V/rated torque

Pulses remaining: 0.05V/reference unit or 0.05V/100 reference units

Communications

Connected Devices

Digital operator (hand-held model), RS-422A port such as for a personal computer

(RS-232C ports under certain conditions)

1:N Communications

Up to N = 14 for RS-422A ports

Axis Address Setting

Set with parameters.

Functions

Status display, parameter setting, monitor display, alarm trace-back display, JOG and

auto-tuning operations, speed, torque reference signal, and other drawing functions.

Others

Reverse rotation connection, origin search, automatic servomotor ID, DC reactor

connection terminal for high power supply frequency control

*1